CFN III Quick Reference
Page 56 MDE-4483 CFN III Quick Reference Guide v3.3 · August 2005
CFN3 to Modem
For CFN3 to modem use part number C05995.
CFN3 to Okidata
For CFN3 to Okidata use part number C05994.
RS-232 Character
Framing
ASCII, 8 data bits, no parity, 1 stop bit.
Print Transaction
Host-Site Mode
Code = PT; options = A
<ENQ>aaPTb<ETB><crc><EOT>
The Site Controller response is:
<STX>aaPTbrrssss0ddddddxyffggggqqqqqqqqooooooo
ppttttyymmddhhnneennnnnnvvvvvvvv
aa...aa,[00..00]tdwkii...iikeeeepppp<ETB><crc><EO
T>
Completed Transaction Codes
Code Message* Meaning
7 Refund transaction is a refund**
8 Return transaction is a return**
9 Payout transaction is a payout**
10 Mem Lost pump control unit’s memory was
lost due to battery failure
40 Pwr Fail transaction terminated due to a
power failure at the pump
control unit
41 normal transaction
42 Timed Out transaction timed out at the
pump
43 Limit pump cut off at limit
45 Reversal transaction is a reversal
50 Unassigned a device completed a transaction
but the Site Controller does not
have a record of it.
52 Gate transaction was started at a gate
controller
54 Aborted transaction was aborted (p ump
was deactivated) before
pumping was completed
55 Delivery transaction is a fuel delivery,
either manually entered at the
card reader terminal*** or
registered by a tank monitor
71 Manual transaction was manually
entered at the card reader
terminal***
77 Pulse err caused by dual pulser failure
78 Prod out pump reports it is out of this
type of product
79 Pump down a pump is not working**
81 Withdrawal transaction was a cash
withdrawal**
* The message printed in the Error field of the
transaction printout.
** Site Controller II and III.
*** Site Controller I only
Site-Host Mode
Standard log in—an example of the sign-on
command and response with calculated CRC-16
check sums:
<ENQ>01CK0GASBOY<ETB>E7B6<EOT>
<STX>01CK00085112514080006000600060001002
0 2V010,<ETB>D389<EOT>