CFN III Quick Reference
MDE-4483 CFN III Quick Reference Guide v3.3 · August 2005 Page 37
ANSI Setup
FKey Lock Off Print National
Feature Lock Off Send All
Keypad Numeric Send Area Screen
Cursor Keys Normal Print Area Screen
Xfer Term EOS Send Term None
Char Mode Multinational Print Term None
Keys Typewriter Print Mode Auto/Normal
VT 100 ID VT 100 Auto Answerback Off
Any commands run at the Site Controller will not be
logged unless you:
• direct output to the logger (use >log with the
command), or
• press CTRL - SHIFT - PRINT SCREEN
simultaneously. Pressing these keys toggles the
Main port output to the logger. (The message
line at the top of the screen toggles between FDX
MAIN and FDX>AUX.)
All other parameters should be set as shown above.
Island Card
Reader I
CPU Board
Part number: C05375.
Switches
DIP Switch Bank 2
DIP switch 2 on the reader terminal CPU board sets
options, including the reader terminal address:
Position & Definition Setting(*=customary)
1 see below *open
2 decimal point
*open=enable
closed=disabled
3 DES PIN encryption
*closed=disabled
open=enabled
4 reader type see below
5 gate reader
*open=disabled
closed=enabled
6 reader type see below
7-10 address see below
Reader Type 2-4 2-6
mag swipe without optical closed closed
mag swipe with optical closed open
mag insert open closed
optical closed open
Notes
Position 2-1 is not used in SC II software versions
1.0 and later. (In software versions 0.2 and before, 2-
1 is the deadman timer switch: open
(default)=enabled, closed=disabled.)
Position 2-5—In SC II software versions 0.2 and
before, 2-5 is the CRC switch; open=CRC enabled,
closed= disabled.
Address 2-7 2-8 2-9 2-10
1 cl cl cl cl
2 cl cl cl op
3 cl cl op cl
4 cl cl op op
5 cl op cl cl
6 cl op cl op
7 cl op op cl
8 cl op op op
9 op cl cl cl
10 op cl cl op
11 op cl op cl
12 op cl op op
13 op op cl cl
14 op op cl op
15 op op op cl
16 op op op op
Jumpers
Jumper Function and/or Normal Setting
K1 Position 1=LCD display
Position 1 and 2=Beckman alphanumeric
display
K2, K3 K2 in position 2 and K3 in position 1=Omron
reader
K2 in position 1 and K3 in position
2=Magstripe reader
K4 ----
K5 Position 2=2K RAM; position 1=8K RAM
K6 Jumpered when using motorized reader