GASBOY Series 1000
2-46 03/07/03
COMBINATIONS (Add if your system has any of these)
Activate Pump w/Data Entries
and MPG/HPG 258
and reasonable odom/hours 221
and fuel allocation 232
Receipt Printer
and MPG/HPG 111
and loadable base pump 11
and fuel delivery and dipstick 27
ROM Total
=
3. Figure out the number of RAM bytes used. Add the calculation totals of each option selected
and write the sum in the space provided at the bottom. This is your RAM Total.
OPTIONS CALCULATIONS
MPG/HPG w/Reas. Odom/Hours
(Number of Vehicles _____
x 15) + 46 =
Reas. Odom/Hours only
(Number of Vehicles _____ x 7) + 46 =
Fuel Allocation (Number of Totalizers _____ x 4) + 44 =
Additional Lockouts (over 550) 4 x number of additional lockouts =
Receipt Printer + 856 =
Tank Monitor + 506 =
Supervisor Cards
+ 12 =
Extended Pump Timeouts
+ 58 =
Pump Switch Timer + 11 =
Fuel Delivery & Dipstick + 6 =
Multi-Level Password
+ 63 =
Loadable Base Pump
+ 4 =
AP w/Data Entries + 9 =
Dual System ID’s + 2 =
RAM Total
=
4. Figure out the amount of available transaction space.
Write the following values: ROM TOTAL (From Step 2):
RAM TOTAL (From Step 3):