GASBOY Series 1000
2-42 03/07/03
Optical Card Systems
NOTE: These calculations do not apply to "A" Systems. For "A" System optical cards, see the
Supplemental "A" System Order Form.
1. Figure out the number of bytes in the transaction record. Only add in the calculations for
manual entry, MPG/HPG, and receipt printer if you have these options.
Field 1 (_____ digits + 1) / 2 (drop decimal remainder) =
Field 2
(_____ digits + 1) / 2 (drop decimal remainder) =
Manual Entry (_____ digits + 1) / 2 (drop decimal remainder) =
MPG/HPG Add 2
=
Receipt Printer Add 1 =
+ 22
Number of Bytes in Transaction Record (Add column) =
2. Figure out the number of ROM bytes used. Scan the list of options. When you locate an
option in your system, copy the number from the bytes column into the calculation column.
Add the STANDARD DEDUCTION and the OPTION values selected. Then add any
applicable numbers from the COMBINATIONS section. This will equal your ROM Total.
STANDARD DEDUCTION 22844
OPTION BYTES
+
Receipt Printer 3171
Multiple Receipts 116
Manual Entry 282
Activate Pump w/Data Entries 290
MPG/HPG w/Reas. Odom/Hours 2919
Reasonable Odom/Hours Only 1603
Fuel Allocation 1507
Dual Lockout 147
Loadable Base Pump 238
Multi-Level Password 557
Supervisor Cards 461
Fuel Delivery and Dipstick 653
Tank Monitor 387
Extended Pump Timeouts 102
Pump Switch Timer 417