FleetKey Systems
03/07/03 4-15
Pump Totalizers
Description Incrementing totalizers are maintained for each hose outlet. As transactions
occur, the totalizer of the corresponding hose is incremented by the transaction
quantity. The pump totalizers can be automatically set back to zero or individually
set to the corresponding mechanical pump totalizer. The totalizers have seven
digits to the left of the decimal point and three digits to the right (xxxxxxx.xxx).
Figure 4-8 shows a pump assignments and totalizer listing initiated by the PP
command.
Figure 4-8. Pump Assignments and Totalizers Listing
Tank Inventory Totalizers
Description The system maintains up to eight tank quantities and allows for setting, adding to,
or subtracting from the inventory level. Each pump is assigned a tank and as
many pumps as desired can be assigned to a particular tank. As transactions
occur, the inventory of the appropriate tank is decremented to show a lesser
quantity. An inventory reorder point can be loaded into the system for each tank.
The reorder point is printed as a reminder when the current tank totalizers are
printed. Once the tank goes below the reorder level, REORDER FUEL prints in
the ERROR field of all transactions withdrawing from that tank until the inventory
is adjusted above the reorder level. Complete pump, tank, and product
assignments may be printed using the TI command (Figure 4-9). The tank
totalizers have seven digits to the left of the decimal point and three digits to the
right (xxxxxxx.xxx)
Figure 4-9. Tank Inventory
Loadable Pump Timeouts
Description The Series 1000 monitors two timeout periods. Timeout values are assigned to
ensure that the pumps are not activated and left unattended.