GASBOY Series 1000
4-28 03/07/03
TRANSACTION STORAGE EXAMPLES
Description The Series 1000 FleetKey System stores up to 844 transactions in memory.
Identification fields and software options use more memory space and therefore
decrease transaction storage.
The table below shows the approximate number of transactions a system will
store based upon various field sizes and optional software.
These examples and the calculations that follow are updated at the .1 release of
each new software version. Intermediate revisions (i.e., .2, .3, etc.) may contain
additional programming changes that will affect these calculations. Contact the
GASBOY Order Department if your ROM total is close to the maximum number of
bytes allowed.
ID Fields
1 2 3 4 Man. Man. MPG Alloc Rcpt TLS Lock Maint. Encd Fuel Total
EMP VEH Entry Lock Hist Blks Point Trans
- - - - - - - - - - 1 - - - 844
4,N 4,N - - - - - - - - 1 - - - 740
4,N 4,N - - 4 - - - - - 1 - - - 696
4,N 4,N - - 4 X - - - - 1 - - - 660
4,N 4,N - - - - 100 - - - 1 - - - 569
4,N 4,N - - - - 500 - - - 1 - - - 387
4,N 4,N - - - - - 100 - - 1 - - - 602
8,N 8,N 4,N - - - - - - - 1 - - - 623
4,N 4,N 4,N - - - - - - - 1 - - - 696
4,N 4,N - - - - - - X - 1 - - - 569
4,N 4,N - - - - - - - X 1 - - - 724
4,N 4,N - - - - - - - - 3 - - - 664
4,N 4,N - - - - - - - - 1 X - - 606
4,N 4,N - - - - - - - - 1 - X - 615
9,N 7,A - - - - - - - - 1 - - - 592
5,A 5,A 5,A 5,A - - - - - - 1 - - - 492
4,N 4,N - - - - 100 - X - 1 - - - 524
4,N 4,N - - - - 100 100 - - 1 - - - 555
4,N 4,N - - - - 100 100 - - 2 - - - 517
4,N 4,N - - 4 X 100 100 - - 1 - - - 487
4,N 4,N - - - - 100 - - - 1 X - - 559
4,N 4,N - - - - 100 - - - 1 - X - 569
4,N 4,N - - - - - - - - 1 - - X 505
4,N 4,N - - - - 100 - - - 1 - - X 464
4,N 4,N - - - - - 100 - - 1 - - X 493
4,N 4,N 4,N - - - - - - - 1 - - X 478
ID fields show digits and format (numeric/alphanumeric)
Manual entry is shown in digits
MPG history is shown in records
Allocation is shown in totalizers
Lockout blocks is shown as number of 10K blocks