16 Insight Interface - CFN3 only Pump Interface Manual v1.3
Gasboy CFN Series 03/20/03
Insight Board Switches
SW1 on the Insight board is used to set the Insight address and baud rate for the site controller
port.
Leave position 1 and 2 alone. These control internal settings for the Insight/pump interface,
which should be set at the factory or by a Tokheim service person. Set each Insight address to
match the site’s DPT address. These are set using positions 3-7.
Set position 8 to OFF for 9600 baud.
3 456 7address
ON ON ON ON ON 1
OFF ON ON ON ON 2
ON OFF ON ON ON 3
OFF OFF ON ON ON 4
ON ON OFF ON ON 5
OFF ON OFF ON ON 6
ON OFF OFF ON ON 7
OFF OFF OFF ON ON 8
ON ON ON OFF ON 9
OFF ON ON OFF ON 10
ON OFF ON OFF ON 11
OFF OFF ON OFF ON 12
ON ON OFF OFF ON 13
OFF ON OFF OFF ON 14
ON OFF OFF OFF ON 15
OFF OFF OFF OFF ON 16
ON ON ON ON OFF 17
OFF ON ON ON OFF 18
ON OFF ON ON OFF 19
OFF OFF ON ON OFF 20
ON ON OFF ON OFF 21
OFFON OFFON OFF 22
ON OFF OFF ON OFF 23
OFF OFF OFF ON OFF 24
ON ON ON OFF OFF 25
OFF ON ON OFF OFF 26
ON OFF ON OFF OFF 27
OFF OFF ON OFF OFF 28
ON ON OFF OFF OFF 29
OFF ON OFF OFF OFF 30
ON OFF OFF OFF OFF 31
OFF OFF OFF OFF OFF 32