Gasboy CFN Series CFN II Quick Reference Version 2.3 Part number: C09159 Rev. 2238 Gasboy International, Inc A Tokheim Com
CFN II Quick Reference 6 C09159 Rev. 2238 LOad Heading (34) enters receipt heading and footing messages. Options: CI I option erases all headin
CFN II Quick Reference C09159 Rev. 2238 7 NExt DAY (151) stops the site, closes the current day, restarts the site, opens the cash drawer for a s
CFN II Quick Reference 8 C09159 Rev. 2238 SENDSLOW <string> string is sent one char. at a time paced about 1/4 second apart. Note: This co
CFN II Quick Reference C09159 Rev. 2238 9 Show transactions after this time -nx(-m) transaction number x or range. Will wrap after 9999 -x Disp
CFN II Quick Reference 10 C09159 Rev. 2238 Print SAles (126) prints sales information. Options: IA I option allows ranges of categories 0 = p
CFN II Quick Reference C09159 Rev. 2238 11 RDEL disk-based command to delete dir 1 and all its contents. READER disk-based configuration program
CFN II Quick Reference 12 C09159 Rev. 2238 REset DIagnostics (65) clears diagnostic error counter. Option: I I option resets after a reconfigur
CFN II Quick Reference C09159 Rev. 2238 13 For D-device, substitute one of the following: S Site Controller C* all Profit Points C1 Profit
CFN II Quick Reference 14 C09159 Rev. 2238 the second number, length, if present, specifies how many characters after the offset will be included
CFN II Quick Reference C09159 Rev. 2238 15 SYS_PAR disk-based configuration program for system parameters; main configuration program for Site Co
CFN II Quick Reference 16 C09159 Rev. 2238 Command Mode Command Argu. Mode Function g n e c go to line number n change begin # end# c make c
CFN II Quick Reference C09159 Rev. 2238 17 %Q Site shift sequence number; each site shift change increments this number. %R Site run level: 0 =
CFN II Quick Reference 18 C09159 Rev. 2238 EPROM Size—K29, K30 EPROM K29 K30 2764 2-3 2-3 27128 2-3 2-3 27256* 1-2 2-3 27512 1-2 1-2
CFN II Quick Reference C09159 Rev. 2238 19 DIP Switch Bank 1 Position & Definition Setting(*=customary) 1 enable battery 1 *on=enabled off
CFN II Quick Reference 20 C09159 Rev. 2238 Console Errors in console-to-Site Controller messages: CRC—bad cyclical redundancy check (CRC) DIE—devi
CFN II Quick Reference C09159 Rev. 2238 21 Profit Point Back panel The back panel of the non-modular Profit Point looks like this: The back panel
CFN II Quick Reference 22 C09159 Rev. 2238 5. Delete entries 6. PLU special operations 0. Return to PLU maintenance menu 1. Se
CFN II Quick Reference C09159 Rev. 2238 23 4. Set up config.pos file 0. Return to configuration menu 1. Network cards configuratio
CFN II Quick Reference 24 C09159 Rev. 2238 35 User defined function (con05) 36 Execute remote command 37 Download site configuration 50 Enter trai
CFN II Quick Reference C09159 Rev. 2238 25 status report 36 — Executes CON06.CMD; default is REPRINT.CMD last, reprint last report 37 — Executes C
CFN II Quick Reference C09159 Rev. 2238 Contents-1 CONTENTS CONTENTS ...1 Site Controll
CFN II Quick Reference 26 C09159 Rev. 2238 Check Point Key Actions The following table shows the default numbers used in assigning actions to Chec
CFN II Quick Reference C09159 Rev. 2238 27 CPU Board, Firmware 5.3 & 5.4 CPU board assembly number: C05836. There are no DIP switch banks on t
CFN II Quick Reference 28 C09159 Rev. 2238 RS-422 Loopback Connector Pin connections: 1 to 3 (black to green) and 2 to 4 (red to yellow). Vacuum F
CFN II Quick Reference C09159 Rev. 2238 29 Star Self Test To start any Star printer’s self test and display its switch settings, turn its power on
CFN II Quick Reference 30 C09159 Rev. 2238 Okidata 184 Printer Setup SW1-1 on Parity: odd SW1-2 on Parity: no SW1-3 on Data bits: 8 SW1-4 off
CFN II Quick Reference C09159 Rev. 2238 31 Event Codes Code Event Code Event 000 Clerk sign-on 012 Enter stand alone mode 001 Clerk sign-off
CFN II Quick Reference 32 C09159 Rev. 2238 This table summarizes the record identifiers that do not appear in the standard reports: Description Id
CFN II Quick Reference C09159 Rev. 2238 33 If an Okidata printer is not directly connected and if you have a Site Controller II version 1.0F or ab
CFN II Quick Reference 34 C09159 Rev. 2238 Test Mode To activate test mode, open the island card reader door, flip the S3 switch on the CPU board
CFN II Quick Reference C09159 Rev. 2238 35 Address 7 8 9 10 1 cl cl cl cl 2 cl cl cl op 3 cl cl op cl 4 cl cl op op 5 cl op cl cl 6 cl op
CFN II Quick Reference Contents 2 C35921 Rev. 2238 LED Indicators...41 Test Points...
CFN II Quick Reference 36 C09159 Rev. 2238 X CANCEL x CLEAR/CANCEL (CLEAR if data entry started; else CANCEL) H Help h Help/Decimal (Decimal if
CFN II Quick Reference C09159 Rev. 2238 37 Jumpers 2-wire operation (default): jumpers 9, 10, and 11 in position 1. Connector J4: 3 - Tx+/Rx+ (CFN
CFN II Quick Reference 38 C09159 Rev. 2238 plug on one end and a DB-9P connector on the other. The wires connect the spare RS-422 jack on the inte
CFN II Quick Reference C09159 Rev. 2238 39 Pump Control Unit EXPMUX CPU Board Part number: C05837 LEDs LED Color Function DL1 green reset high D
CFN II Quick Reference 40 C09159 Rev. 2238 CMOS CPU Board Part number: C05321 LEDs LED Color Function L1 red 422 transmit L2 red 422 receive L3,
CFN II Quick Reference C09159 Rev. 2238 41 9800 Pump Dispenser CPU Board Jumpers Jumper K1 is set according to the size of the RAM IC in socket U1
CFN II Quick Reference 42 C09159 Rev. 2238 Pulse Rate 2-1 2-2 2-3 1 cl cl cl 10 op cl cl 100 cl op cl 250 op op cl 500 cl cl op 1000 op cl
CFN II Quick Reference C09159 Rev. 2238 43 New installation: • Connect a Tokheim Splitter to port 1 or port 3 on the SC II. • Connect a C05578
CFN II Quick Reference 44 C09159 Rev. 2238 23 — Wayne 3 product blender, hoses 1, 3, and 5. For Wayne products V580 and V590U. Previously these pu
CFN II Quick Reference C09159 Rev. 2238 45 Position & Definition Setting(*=customary) 1 (see below) 2 # of pumps per loop *open=6 dual p
CFN II Quick Reference C09159 Rev. 2238 1 Site Controller II Command Summaries, Version 2.3 General Command Summary [...] Square brackets mean tha
CFN II Quick Reference 46 C09159 Rev. 2238 selection to work. • all Wayne dispensers must be configured in sequential, consecutive order. All Wa
CFN II Quick Reference C09159 Rev. 2238 47 Cabling - over 8 feet Cabling the TLS-350 for Tank/Level Data The TLS may be connected on either the Co
CFN II Quick Reference 48 C09159 Rev. 2238 RS485 loops. This sets the communication parameters to 9600, odd, 1 stop bit, 7 data bits, and security
CFN II Quick Reference C09159 Rev. 2238 49 3. Start counting turns. 4. Continue turning R1 clockwise until the data starts to scramble again. 5.
CFN II Quick Reference 50 C09159 Rev. 2238 RS-232 Character Framing ASCII, 8 data bits, no parity, 1 stop bit. Print Transaction Host-Site Mode C
CFN II Quick Reference C09159 Rev. 2238 51 Completed Transaction Codes Code Message* Meaning 7 Refund transaction is a refund** 8 Return tra
CFN II Quick Reference 52 C09159 Rev. 2238 <filename uses the commands from the named file as input. >filename puts the output of the comman
CFN II Quick Reference 2 C09159 Rev. 2238 -E n1 text Number of case to execute is entered by user; n1 is total number of cases (except default, if
CFN II Quick Reference C09159 Rev. 2238 3 DISKCOPY disk-based command to copy files from a floppy diskette in drive A to another floppy diskette,
CFN II Quick Reference 4 C09159 Rev. 2238 operation. Options: CI I option enables and re-initializes all TMSs EXit (27) exits command mode, en
CFN II Quick Reference C09159 Rev. 2238 5 IF command for conditional branching in command files. Options: -[!] {Y [text] | E filename | {= | <