10 Tokheim Pump Interface Manual v1.3
Gasboy CFN Series 03/20/03
• SW1, position 1 is not used for releases prior to 1.0D of the Gasboy DPT program.
For release 1.0D and above, SW1, position 1 is set to OFF if the printer has a cutter bar;
ON if the printer has a tear bar.
• SW1, position 2 determines the UDC poll address for the Premier pump head. SW1,
position 2 must be set to On for side A and OFF for side B.
• The Premier Pump head address is set in mode 23.
• SW1, positions 3-7 indicate the address for the DPT. Use the following table to set the
address.
• SW1, position 8 controls the line display. ON for 4-line display and OFF for 2-line dis-
play.
Tokheim 69 box
A Tokheim 69 box is used for wiring a DPT to a CFN2 or CFN3. The DPTs are wired from J2
through J5 in the 69 box. The GASBOY RS-422/485 J-Box is wired to J1 of the 69 Box. If the 69
Address 1-7 1-6 1-5 1-4 1-3
1 ononononon
2 ononononoff
3 onononoffon
4 onononoffoff
5 ononoffonon
6 ononoffonoff
7 ononoffoffon
8 ononoffoffoff
9 on off on on on
10 on off on on off
11 on off on off on
12 on off on off off
13 on off off on on
14 on off off on off
15 on off off off on
16 on off off off off
17offonononon
18offonononoff
19 off on on off on
20 off on on off off
21 off on off on on
22 off on off on off
23 off on off off on
24 off on off off off
25 off off on on on
26 off off on on off
27 off off on off on
28 off off on off off
29 off off off on on
30 off off off on off
31 off off off off on
32 off off off off off